Each CVC is custom built to accommodate load size and delivery rate required. Delivery rate or Throughput (loads per minute) is based on platform (carrier) spacing and belt speed. Minimum platform spacing is a function of the load length and load height.
Pflow will work with you to optimize the equipment to your specific need. Generally a lower belt speed will enhance operation and equipment life. When possible, add platforms to achieve required throughput instead of increasing belt speed.
Payload Capacity: up to 200 lbs./platform
Belt Speed: 60 ft./min. standard, up to 120 ft/min. maximum
Throughput: up to 30 loads per minute
Load Pattern: "Z"
Platform Size: up to 24" wd x 36" lg (size based on load size)
Elevation Change: up to 80
Lower Level TOR: 12" minimum
Full-height safety enclosures
Torque limiter (slip clutch)
Photocell to detect misfed or dropped load Tunnel or Scoop guard over infeed conveyor
Standard Drive: 1 HP Eurodrive worm gear motor
Supply Power: 230/460 VAC, 3 PH, 60 HZ, 3.70/1.8 Amp
Duty Rating: Continuous duty
Recommended Service: 15 Amp
Single-direction operation (up or down) including control of infeed conveyor section. Control panel is NEMA 12 and pre-mounted to lift structure. Panel includes Programmable Logic Controller and step-down transformer for 120VAC control voltage. All logic is PLC based. Control buttons on panel include Power On with light, E-Stop, and Manual/Auto mode, Lift Forward/Reverse, Conveyor Forward/Reverse selector switches.
Inputs from customer controls include: Lift enable/E-stop, Run and Discharge full. Outputs to customer controls include: Safeties OK, Lift paused (discharge full) and OK to infeed load.
Pflow CVCs ship assembled, wired and tested. Units with vertical height greater than 20 ft. ship in stackable sections after being fully assembled and tested.
Options include: Reversible operation, soft start/variable speed, epoxy paint, plexiglas enclosures.